Título: | Proposta de avaliação qualitativa para o monitoramento do aerosol marinho |
metadata.dc.creator: | Araújo, Ariel Carvalho |
metadata.dc.contributor.advisor1: | Guimarães, Elvio Antonino |
metadata.dc.contributor.referee1: | Guimarães, Elvio Antonino |
metadata.dc.contributor.referee2: | Fortes, Adriano Silva |
metadata.dc.contributor.referee3: | Carvalho, Jenner Miranda de |
metadata.dc.description.resumo: | O ataque químico a superfícies de fachadas e ao aço do concreto armado por cloretos é uma das causas de patologias em construções mais frequentes em regiões litorâneas, nas quais é elevada a concentração de sais nos depósitos produzidos por spraymarinho. Como uma forma de auxiliar na prevenção dessas patologias, esse trabalho tem como objetivo desenvolver um protótipo de sensor e sistema de monitoramento de acúmulo de depósitos salinos em superfícies de paredes de fachadas de construção. Baseando-se nas propriedades de moderada condutividade elétrica destes depósitos, sob a influência da umidade atmosférica, um sensor com substrato de fenolite e trilhas condutoras de cobre foi fabricado e testado em ambiente externo, exposto à atmosfera, para verificação de sua viabilidade de aplicação no monitoramento proposto. Além disso, amostras de depósitos salinos, coletadas da cortina de vidro e da janela de um apartamento próximo à orla marítima de Salvador, foram analisadas por técnicas de determinação de condutividade elétrica, microscopia eletrônica de varredura e espectroscopia de energia dispersiva de raios-X. De acordo com os resultados obtidos, as amostras coletadas apresentaram valores de condutividade elétrica e salinidade dentro da faixa esperada para exposições a aerossóis marinhos, bem como a presença de cloreto de sódio, como principal componente, de acordo com o observado pelas micrografias e dados de composição elementar encontrados. Os valores de resistência normalizada, aliados aos dados de medição obtidos durante a exposição do sensor ao ambiente externo, possibilitaram a validação do potencial de utilização do sistema desenvolvido para o monitoramento de ambientes com alta salinidade, baseado na estimação qualitativa da concentração de íons cloreto na atmosfera marinha. Em contraposição aos métodos analíticos clássicos, como o método da vela úmida, que necessitam de um tempo de exposição ao ambiente em estudo razoavelmente elevado, podendo chegar a um mês de exposição para uma avaliação precisa, o método estudado neste trabalho possui a vantagem de proporcionar a obtenção de uma avaliação qualitativa em tempo de resposta praticamente imediato. |
Resumo: | Chemical attack on facade surfaces and reinforced concrete steel by chlorides is one of the most common causes of pathologies in buildings in coastal regions, where the concentration of salts in deposits produced by sea spray is high. As a way of helping to prevent these pathologies, this work aims to develop a prototype sensor and monitoring system for the accumulation of saline deposits on building facade wall surfaces. Based on the properties of moderate electrical conductivity of these deposits, under the influence of atmospheric humidity, a sensor with phenolic substrate and copper conductive tracks was manufactured and tested in an external environment, exposed to the atmosphere, to verify its feasibility of application in the proposed monitoring. Furthermore, samples of saline deposits, collected from the glass curtain and the window of an apartment near the Salvador seafront, were analyzed using electrical conductivity determination techniques, scanning electron microscopy and energy dispersive X-ray spectroscopy. According to the results obtained, the collected samples presented electrical conductivity and salinity values within the expected range for exposure to marine aerosols, as well as the presence of sodium chloride, as the main component, according to as observed by the micrographs and elemental composition data found. The normalized resistance values, combined with measurement data obtained during the exposure of the sensor in an outdoor environment, made it possible to validate the potential for use of the system developed for monitoring environments with high salinity, based on the qualitative estimation of the concentration of chloride ions in the marine atmosphere. In contrast to classical analytical methods, such as the wet candle method, which require a reasonably long exposure time to the environment under study, reaching up to one month of exposure for an accurate assessment, the method studied in this work has the advantage of providing a qualitative assessment in a practically immediate response time. |
Palavras-chave: | Patologias Aerosol marinho Monitoramento Pathologies Marine spray Monitoring |
metadata.dc.subject.cnpq: | CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL |
metadata.dc.language: | por |
metadata.dc.publisher.country: | Brasil |
Editor: | Instituto Federal de Educação, Ciência e Tecnologia da Bahia |
metadata.dc.publisher.initials: | IFBA |
metadata.dc.publisher.department: | Departamento de Ensino Técnico |
Citação: | ARAÚJO, Ariel Carvalho. Proposta de avaliação qualitativa para o monitoramento do aerosol marinho. Orientador: Elvio Antonino Guimarães. Trabalho de Conclusão de Curso (Técnico em Edificações) -- Instituto Federal da Bahia, Campus Salvador, Salvador, 2023. |
metadata.dc.rights: | Acesso Aberto Attribution-NonCommercial-NoDerivs 3.0 United States |
metadata.dc.rights.uri: | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ |
URI: | https://repositorio.ifba.edu.br/jspui/handle/123456789/542 |
Data do documento: | 30-Nov-2023 |
Aparece nas coleções: | Trabalhos de Conclusão de Cursos (TCCs) |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
TCC_Ariel Araujo_Edif.pdf | TCC | 11.1 MB | Adobe PDF | Visualizar/Abrir |
Este item está licenciada sob uma Licença Creative Commons
Ferramentas do administrador